6 way Nurse Call indicator, global silence no reset no PSU
£181.06
Ex Vat
In stock
Product code
MG311000
Nurse Call indicator with global silence no reset no PSU
Nurse Call annunciators in principle have a similar operation to the Multiguard general purpose annunciators. There is a Silence button F1 but no reset button or isolate facilities are fitted. Integral power supplies are not usually fitted to these versions as extra power is needed for call points and overdoor lights etc...
The control logic is non-latching. When a call is made an audible warning is given by an integral piezo sounder and the relevant zone LED flashes. The sounder can be silenced at the panel but must be reset at the call point. Nurse call annunciators have facilities for Late Attendance indication. When a late attendance condition is generated the Multiguard emits an interrupted pulsed tone accompanied by an interrupted flashing LED for the relevant zone. Similar but continuous pulsed signals are used for Emergency Re-call. Signals are graded - late attendance takes priority over standard calls and emergency re-call take priority over late attendance. Manual and Electronic Call Points can be used on the same installation. However, late attendance and emergency re-call are only possible with electronic call points.
Specification
The control logic is non-latching. When a call is made an audible warning is given by an integral piezo sounder and the relevant zone LED flashes. The sounder can be silenced at the panel but must be reset at the call point. Nurse call annunciators have facilities for Late Attendance indication. When a late attendance condition is generated the Multiguard emits an interrupted pulsed tone accompanied by an interrupted flashing LED for the relevant zone. Similar but continuous pulsed signals are used for Emergency Re-call. Signals are graded - late attendance takes priority over standard calls and emergency re-call take priority over late attendance. Manual and Electronic Call Points can be used on the same installation. However, late attendance and emergency re-call are only possible with electronic call points.
Specification
- Six zone Nurse Call annunciator
- Custom designed case
- Central silence
- Remote reset
- 12vdc powered
- Integral piezo sounder
- Unique labelling system
- Late attendance facility
- Emergency recall facility
- Range of accessories
- Dimensions 197 x 137 x 72mm
- UKCA and CE marked, ROHS compliant
- Manufactured in the Uk
Country of Origin | UK |
---|---|
Condition | New |
SKU | MG311000 |
Associated Product Codes | MG311000 |
Warranty | 3 Years |
- | ![]() |
- | ![]() |
- | ![]() |
Write Your Own Review